beautypg.com

Tjernlund SS2 SideShot (Discontinued Version - Pre UC1 Universal Control) 8504063 Rev B 11/99 User Manual

Page 17

background image

16

MAINTENANCE

INSTALLER AND USER REQUIREMENTS

Installer must visually inspect unit annually.

• Installer must verify over-fire draft, CO

2

and smoke readings are all correct. See “Draft Adjustment Procedure” on page 12.

• Inspect vent pipe for evidence of corrosion. If any corrosion is found replace vent pipe and inspect venter.

IMPELLER INSPECTION

We recommend that the SS2 impeller be inspected annually. Improper burner adjustment can cause excessive particulate build
up over time and impair venter performance. NOTE: See “SS2 Terminology” on page 3 for isometric diagram when following
impeller inspection procedure.

NOTE: The following inspection procedure should be done when SS2 is mounted. Use care so hardware is not lost.

1. To examine impeller, remove vent pipe and SS2 inlet pipe by twisting counter clockwise.

2. Remove (7) screws which hold Cover Plate to Vent Cabinet.

3. Remove flexible tubing from Fan Prover sensing tube and remove (8) nuts which hold inlet assembly to Venter Housing.

An impeller that exhibits large amounts of particulate should be cleaned with a soft metal wire brush and soot cleaner. Clean
each blade, as well as the rest of the impeller. An impeller that appears to be out of round should be replaced with a new impeller.
After cleaning or replacing impeller, perform “Draft Adjustment Procedure” on page 12.

MOTOR OILING
The SS2 Motor has sealed ball bearings and requires no oiling.

HOW TO OBTAIN SERVICE ASSISTANCE

1.

If you have any questions about your Power Venter or if it requires adjustment, repair or routine maintenance, we suggest
that you contact your installer, contractor or service agency.

2.

If you require technical information contact Tjernlund Products, Inc. at 1-800-255-4208.

When contacting Tjernlund Products, Inc., please have the following information available:

1.

Model of the Power Venter as shown on the label attached to Power Venter.

2

Name and address of installer and any service agency who performed work on Power Venter.

3.

Date of original installation and dates any service work was performed.

4.

Details of the problem as you can best describe them.

LIMITED PARTS WARRANTY AND CLAIM PROCEDURE

Tjernlund Products, Inc. warrants the components of the SideShot for two years from date of installation. This warranty covers
defects in material and workmanship. This warranty does not cover normal maintenance, transportation or installation charges for
replacement parts or any other service calls or repairs. This warranty DOES NOT cover the complete SS2 if it is operative, except
for the defective part.

Tjernlund Products, Inc. will issue credit or provide a free part to replace one that becomes defective during the two year warranty
period. If the part is over 30 months old, proof of date of the installation in the form of the contractor sales/installation receipt is
necessary to prove the unit has been in service for under two years. All receipts should include the date code of the SideShot to
ensure that the defective component corresponds with the complete unit. This will help preclude possible credit refusal.

1.) Follow troubleshooting guide to determine defective component. If unable to determine faulty component, contact your

Tjernlund distributor or Tjernlund Products Technical Customer Service Department at 1-800-255-4208 for troubleshooting
assistance.

2.) After the faulty component is determined, return it to your Tjernlund distributor for replacement. Please include SideShot date

code component was taken from. The date code is located on the Electrical Box coverplate. If the date code is older than 30
months you will need to provide a copy of the original installation receipt to your distributor. Credit or replacement will only be
issued to a Tjernlund distributor after the defective part has been returned prepaid to Tjernlund.