2 virtui configuration, 1 downloading to the tracer avi, Downloading to the – Rice Lake Tracer AVi - v2.0 User Manual
Page 16

12
Tracer AVi
Installation Manual
3.2
VIRTUI Configuration
VIRTUi
can be used to set
iQube
configuration parameters. When configuration is complete, data is downloaded
to the
iQube
.
To configure the
iQube
using
VIRTUi
:
1. With the PC and
iQube
connected and the
VIRTUi
program running, select
iQube
Configuration
from the
Settings
menu.
Figure 3-10. VIRTUi Tracer AVi Display
2. Select the
Cells
display. Use this display to select the load cell used in the
Tracer AVi
system by checking
the box to the left of the cell. Enter load cell data such as factory sensitivity, serial number, and capacity
on the General Information sheet for the cell.
3. Select the
Platforms
display. The cell that was checked on the Cells screen is now listed as Available
Load Cell for the
iQube
.
4. Click on
Platform 1
.
5. Double-click on the load cell to move the cell into the Assigned Load Cell column for Platform 1.
As the cell is added to the Assigned Cell column, a Section Format Diagram is displayed at the bottom of
the screen.
6. Select the
Systems
display.
7. Click on
System 1
.
8. Platform 1 is now shown in the Assigned Platforms field. Click the
Platform 1
box to assign Platform 1 to
System 1. Use the General display to enter scale system parameters.
3.2.1
Downloading to the Tracer AVi
Once configuration is complete, you must download the configuration data from the PC to the
iQube
.
1. Select
Send Configuration
to write the values to the
iQube
.
2. Click
Begin
to initiate the download. Downloading may take up to 30 seconds.