1 display windows and annunciators, 2 error messages, 1 weight calibration – Rice Lake RS-130 - Operation Manual User Manual
Page 10

6
RS-130 Operation Manual
3.1
Display Windows and Annunciators
Table 3-2. Display Windows
Display Window
Description
WEIGHT
Displays the weight of the object on the platter.
UNIT PRICE $
Displays the unit price of the object on the platter.
TOTAL $
Displays the total amount owed (weight multiplied by unit price).
Indicates scale
is in NET mode
Indicates scale
is at ZERO
Indicates weight
is in either lb, kg,
or oz (oz not
available in
Canada)
Status of battery charging
Red: initial charge
Orange: charging
Green: fully charged
Indicates the
amount of cash
received
Indicates the
amount of change
due
Figure 3-1. Front Display Annunciators
3.2
Error Messages
Table 3-3. Error Messages and Troubleshooting
Display
Description
Corrective Action
WEIGHT
display shows
"Err-1"
IC93C66 data-loss or IC93C66 damaged/
faulty
Contact your nearest RLWS dealer
WEIGHT
display shows
"Err-3"
At power-up, the weight on the platter is
more than 5% of the maximum capacity
Remove the weight from the scale, or to under 5%
of capacity and restart the scale
TOTAL $
display shows
"E"
The total price value is larger than 9999.99
Remove the measured object from the platter and
press CLEAR to clear the unit price setting
Table 3-3 describes error messages that may be shown on the RS-130 display.
0 - 9 Numeric
Keys
Enter the numeric value required.
• Use the numeric keys to enter the price-per-unit, PLU number, cash received
Press and hold the 0 key to show the battery voltage in the
WEIGHT
display.
•
6.1
-
6.5
means the battery is fully-charged.
• Less than
5.6
means the battery is in low-charge.
• Press the
CLEAR
key to return the display to normal operating mode.
Key
Function/Description
Table 3-1. Function Keys