5 remote display/indicator programs, Remote display / indicator programs, Program # indicator and operating mode – Rice Lake Remote Displays/Scoreboards - 234HE User Manual
Page 7

6
5.
Remote Display / Indicator Programs
Program #
Indicator and Operating Mode
F1_5-1D
UMC1000, UMC2000, IQ600, IQ700 — Continuous
F1_5-1D
Thurman EDS4 - EPROM in indicator is Continuous Condec format
F1_5-2B
UMC 1000, 2000 — Demand
F1_5-3B
Toledo 8140, 8142, 8530, 8132
1
, 9481 — Continuous
F1_5-3B
Fairbanks 9201RS-232 (Use COM port 1 only)
F1_5-4D
IQplus 800/810, IQplus 310 Continuous (End of line set to CR/LF)
F1_5-5A
StreeterAmet 9000 — Continuous
F1_5-6A
Cardinal 738 — Continuous
F1_5-7A
Western DF1000 — Continuous
F1_5-8A
Pennsylvania 5600 — Continuous
F1_5-9A
Flexweigh DWM IV — Continuous
F1_5-10A
IDS print w/BCD to 20 mA conversion — Continuous
F1_5-11A
AD 4321 — Continuous (Format 1, display will not show negative sign)
F1_5-12A
IQ700 Truck ID for KBB 8-1, Ver. EF EPROM
F1_5-13A
Analogic 5316 — Continuous, HB 44 (EPROM 13.0 shows gross only)
F1_5-14A
Electroscale 533 — Continuous
F1_5-15A
IQ700, IQplus 310 Demand (Net or Gross) with Time and Date
F1_5-16A
WI-110, WI-120, WI-130 — Continuous
2
F1_5-17A
Toledo 8142 with BCD Converter
F1_5-18A
Doran 7000 — Continuous
F1_5-19A
Fairbanks 90-164-1, 90-166-1, 9201 (out Com 2) — Continuous (20 mA passive only)
F1_5-1C
UMC 1000, UMC 2000, IQ600, IQ700 — Continuous
F1_5-21A
Electroscale 551 — Continuous
F1_5-22A
Analogic 5316, EPROM Revision 13.0.9 — Continuous
F1_5-23A
General Freedom I and II — Continuous
F1_5-24A
ACCU-WEIGH SEP-12K, Format 8 — Continuous
F1_5-25A
Kubota KA-10 — Continuous
F1_5-26A
Flexweigh DWMIV Continuous w/Post & Preamble (02H, 03H)
F1_5-27A
MSI TRANS-WEIGH — Continuous
F1_5-28A
OHAUS 1150 — Continuous
F1_5-29A
Hardy HI 2151 WC — Continuous
F1_5-30A
Pennsylvania 3100 — Continuous
F1_5-31A
IQplus 800/810 — Demand (Standard default format)
F1_5-32A
IQplus 310 — Demand (Net Weight Only)
F1_5-33A
IQplus 310 — Demand (Gross Weight Only)
F1_5-34A
Fairbanks 90-163-1 — Continuous
F1_5-36A
IQ700, IQplus 310, — Demand (Net or Gross) with Time and Date
F1_5-37A
Tyrel TC-10 / Howe-Richardson HR500k Continuous
F1_5-38A
Tara TR-1 Continuous, 1200 baud, fixed 8 bits, no parity, 2 stop bits
F1_5-39A
Allegany Mega 8—Continuous
3
F1_5-40A
A-N-D FG Bench Scale
F1_5-41A
Cardinal 748 — Continuous
F1_5-42A
3-weight 810 — Continuous
4
Notes:
1
The Toledo 8132 meter will not work with the 234HE without special programming to operate the 234HE at 4800 baud.
2
The WI130 indicator must be programmed to stream out in the standard Weightronix format to use the WI110/WI120 flip digit driver.
3
The Allegany Mega 8 sends out eight weight display digits. The EL234HE Remote Display shows the least significant six digits.
4
This special format contains three weight strings within one serial string. Dip switches 7 and 8 in switchbank 2 control which of the three
strings are displayed as follows:
2-7
2-8
String Displayed
off
off
1st
off
on
2nd
on
off
3rd