14
Bariatric Wheelchair Technical and Operating Manual
13
Message style on
weight algorithm
MESS <-> WEIGH
This displays the message that will show
on the indicator display. To change the
message, press the Kg-Lb key.
WEIGH,
LIVE,
- - - - - -
To advance to the next step, press the
REWEIGH key.
143
This allows for setting
the baud rate of the
RS-232 connection
BAUd <->
Default - 9600
To change the baud rate, use the numeric
data entry (See “Numeric Data Entry” on
page 12.)
To advance to the next step, press the
REWEIGH key.
15
Optional features
Option 1 allows the
selection of unit of
measure (UOM) in
calibration and
programming.
OP1 = 1
Hold the Kg-Lb key for browsing through
the options. Double click on the Kg-Lb
key to change the options value or
to advance to the next step, press the
REWEIGH key.
OP1 = Unit of measure (UOM) in
calibration and programming.
0=Kg
1=Lb
Option 2 allows the
scale to work only in
Kg.
OP2 = 0
Hold the Kg-Lb key for browsing through
the options. Double click on the Kg-Lb
key to change the options value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1= Enable
This option works only if Option 3 is
disabled
Option 3 allows the
scale to work only in
Lb.
OP3 = 0
Hold the Kg-Lb key for browsing through
the options. Double click on the Kg-Lb
key to change the options value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1=Enable
Option 4, the scale
must be stable to
show a Kg or Lb
weight reading. You
can enable or disable
this.
OP4 = 0
Hold the Kg-Lb key for browsing through
the options. Double click on the Kg-Lb
key to change the options value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1=Enable
Note: won’t show lb or kg until the scale
is at a standstill.
Option 5 allows for live
or dynamic weighing
OP5 = 0
Hold the Kg-Lb key for browsing through
the options. Double click on the Kg-Lb
key to change the options value or
to advance to the next step, press the
REWEIGH key.
0=Disable
1=Enable
Step
Function
Display
Available Parameters
Table 5-1. Configuration Mode Menu