Rice Lake SURVIVOR Paramounts HE Medium Capacity User Manual
Page 18

14
Paramount Installation Guide
cable end of the load cell. Insufficient torque may allow the rear of the load
cell to lift; too much torque may cause screw failure.
6. Lower the vessel onto the load cell by raising the jack nut while holding the
jam nut with a second wrench. Lock the jack nut against the jam nut. See Sec-
tion 4.2 for wiring and trimming information.