UNIT
WEIGHT
NET/
GROSS
MOVEMENT
ON
OFF
-
+
*
#
RE
ZERO
TARE
PIECES
kg
lb
Rezero
Eliminates weight from the Weight display with no tare in the system and causes it to show
a true 0. The rezero button will not function when the indicator is in motion.
Tare
Zeroes the weight display by placing a displayed weight into the tare register. The system
must be in a standstill condition before a tare can be registered. The tare register is normally
used to store a value such as a container weight.
Pieces
Sets the number of sample pieces. Press after placing your 10-piece sample on the platform
or keying in the sample size number with the numeric keys. On multichannel units, the
correct scale must be selected.
kg - lb
Toggles the display between pound (lb) and kilogram (kg). The scale powers up in the
pound mode.
Unit Weight
Used to enter weight per 1000 count of pieces or is pressed after you enter a weight value
using the keypad.
When entering an average piece weight, remember to enter the total weight of 1000 pieces.
This method provides an additional three decimal places of resolution in piece count
calculations. For example, the weight per 1000 count of pieces weighing 0.1 lb each would
be 100.0 lb (0.1 x 1000).
Net/Gross - Movement
Toggles between net weight and gross weight display modes. In the gross display mode the
gross weight is displayed, the gross annunciator is lit, and a computation of piece weight is
not available. A tare must be in the system to enter the net mode. In the net mode, the tare
annunciator is lit.
On - Off
Powers up and powers down the scale.
- (minus)
Used to subtract parts in an accumulation operation.
+ (plus)
Used to add parts in an accumulation operation.
* (total)
Used to total an accumulation operation and exit the program mode.
# (code)
Used to enter product code numbers, enter parts into the scale inventory, and remove
existing parts.