Table 9-6 on – Rice Lake 920i Installation Manual V3.13 User Manual
Page 98

92
920i
Installation Manual
Command
Description
Values
SP.KIND#n
Setpoint kind
OFF, GROSS, NET, –GROSS, –NET, ACCUM, ROC, +REL, –REL,
%REL, RESREL, PAUSE, DELAY, WAITSS, COUNTER, AUTOJOG,
COZ, INMOTON, INRANGE, BATCHPR, TIMER, CONCUR, DIGIN,
AVG, TOD, DELTA, CHWEI, PLSCNT, PLSRAT, ALWAYS, NEVER,
DINCNT
SP.VALUE#n
Setpoint value
number
SP.SOURCE#n
Source scale
SCALE1, SCALE2, SCALE3…SCALEx
SP.COAST#n
Pulse counter coast
number
SP.TRIP#n
Trip
HIGHER, LOWER, INBAND, OUTBAND
SP.BANDVAL#n
Band value
number
SP.HYSTER#n
Hysteresis
number
SP.PREACT#n
Preact type
OFF, ON, LEARN, FLOW
SP.PREVAL#n
Preact value
number
SP.PREADJ#n
Preact adjustment percentage
number
SP.PRESTAB#n
Preact learn stability
number
SP.PCOUNT#n
Preact learn interval
number
SP.TOLBAND#n
Target tolerance
number
SP.TOLCNT#n
Tolerance count
number
SP.BATCH#n
Batch step enable
OFF, ON
SP.CLRACCM#n
Clear accumulator enable
OFF, ON
SP.CLRTARE#n
Clear tare enable
OFF, ON
SP.PSHACCM#n
Push accumulate
OFF, ON, ONQUIET
SP.PSHPRINT#n
Push print
OFF, ON, WAITSS
SP.PSHTARE#n
Push tare
OFF, ON
SP.ALARM#n
Alarm enable
OFF, ON
SP.NAME#n
Setpoint name number
NONE, 1–60
SP.ACCESS#n
Setpoint access
OFF, ON, HIDE
SP.DSLOT#n
Digital output slot
NONE, SLOTx
SP.DIGOUT#n
Digital output
BITx
SP.SENSE#n
Digital output sense
NORMAL, INVERT
SP.BRANCH#n
Branch destination
0, 1-100
SP.RELNUM#n
Relative setpoint number
1–100
SP.START#n
Starting setpoint
1–100
SP.END#n
Ending setpoint
1–100
SP.DISLOT#n
Digital input slot
NONE, SLOTx
SP.MASK#n
Digital input mask
number
SP.NSAMPLE#n
Number of samples
number
SP.TIME#n
Trip time
hhmm
SP.DURATION#n
Trip duration
hhmmss
SP.VUNDER#n
Underrange value
number
SP.VOVER#n
Overrange value
number
SP.DUNDER#n
Underrange digital output
BITx
Table 9-6. SETPNTS Serial Commands