Rice Lake 920i Installation Manual V3.13 User Manual
Page 96

90
920i
Installation Manual
EDP.ADDRESS#p
Port RS-485 address
0, 1–255
EDP.STREAM#p
Port streaming
OFF, LFT, INDUST, 4KEYS, KEYPAD, DISPLAY
EDP.SOURCE#p
Port source scale for output
scale_number
EDP.SFMT#p
Port custom stream format
0-50 characters
STR.POS#p
Custom stream identifiers
Specify replacement text for token
Example: STR.PRI#1=L
See Section 10.6 on page 109 for more information about custom
stream formatting.
STR.NEG#p
STR.PRI#p
STR.SEC#p
STR.TER#p
STR.GROSS#p
STR.NET#p
STR.TARE#p
STR.MOTION#p
STR.RANGE#p
STR.OK#p
STR.INVALID#p
STR.ZERO#p
For commands including “#p”, p is the serial port number.
Command
Description
Values
Table 9-4. SERIAL Port Serial Commands (Continued)
Command
Description
Values
SD
Set date
MMDDYY, DDMMYY, YYMMDD, or YYDDMM. Enter six-digit
date using the year-month-day order specified for the
DATEFMT parameter, using only the last two digits of the year.
ST
Set time
hhmm (enter using 24-hour format)
DATEFMT
Date format
MMDDYYYY, DDMMYYYY, YYYYMMDD, YYYYDDMM
DATESEP
Date separator
SLASH, DASH, SEMI
TIMEFMT
Time format
12HOUR, 24HOUR
TIMESEP
Time separator
COLON, COMMA
DECFMT
Decimal format
DOT, COMMA
DSPRATE
Display rate
1–80, in100-ms intervals
CONSNUM
Consecutive numbering
0–9999999
CONSTUP
Consecutive number start-up value
0–9999999
UID
Unit identifier
aaaaaaaa (up to 8 alphanumeric characters)
TRUCK
Truck in/out mode
OFF, MODE1, MODE2, MODE3, MODE4, MODE5, MODE6
ALIBI
Alibi data storage
OFF, ON
CFGPWD
Configuration password
0, 1–9999999
SPPWD
Setpoint password
0, 1–9999999
SK#1–SK#10
Softkey assignment
Blank, TimeDate, DspTar, DspAcc, DspROC, SetPt, BatStrt,
BatStop, BatPause, BatRst, WeighIn, WeighOut, TrkReg, UID,
SclSel, Diagnostics, Alibi, SKUD1–SKUD10
SKT#1–SKT#10
User-defined softkey text
—
Table 9-5. FEATURE Serial Commands