Rice Lake 920i Programmable HMI Indicator/Controller - Profibus DP Interface User Manual
Page 17

GSD File
13
; Slave-Specification:
Freeze_Mode_supp= 1
; Freeze mode is supported
Sync_Mode_Supp = 1
; Sync-mode is supported
Auto_Baud_supp = 1
; Auto baud rate detection supported
Set_Slave_Add_Supp= 0
; Set_Slave Add is not supported
Min_Slave_Intervall= 1
; 100us between poll cycles of the slave
Modular_Station= 1
; Modular device (can be set up multiple ways)
Max_Module
= 1
; Maximum number of modules
Max_Input_Len
= 8
; Maximum number of input bytes
Max_Output_Len = 8
; Maximum number of output bytes
Max_Data_Len
= 16 ; Maximum number of bytes transferred
Fail_Safe
= 0
; State CLEAR not accepted
Max_Diag_Data_Len= 6
Modul_Offset
= 1
; First slot number.
Slave_Family
= 3@TdF@OTHER; Function class: I/O
; UserPrmData: Length and Preset:
User_Prm_Data_Len= 0
;
Module
= "4 WORDS I/O Consistent " 0xD3,0xE3
1
EndModule