Kontron MARS Smart Battery Kit User Manual
Page 32
MARS User´s Guide
In the following the most important information is shown, that can be read out of the SBS Manager
and the both batteries.
SBS Manager: SM-Bus address 14h (look also datasheet of LTC1760)
h
Information of the system status
• Which battery is present, is charged/discharged, sends a calibrate request
• If AC is present
• If power is good
• A calibration is in process
Smart Batteries: SM-Bus address 16h (look also datasheet of the used Smart Battery)
• Average Time to Empty
• Remaining Capacity Alarm
• Average Time to Full
• Remaining Time Alarm
• Charging Current
• Temperature
• Charging Voltage
• Voltage
• Battery Status (fully charged, over charged,
over temperature alarm)
• Current
• Relative State of Charge
• Cycle count
• Absolute State of Charge
• Design Capacity
• Remaining Capacity
• Design Voltage
• Full Charge Capacity
• Run Time to Empty
h
It is possible to get only information of one battery at one time. After this the SM-Bus must be
connected to the other battery. This should be done by sending the hexadecimal word 1000h
Note:
(battery 1) or 2000h (battery 2) at command Code 01h to address 14h via the SM-Bus. (default:
battery 1)
Appendix B:
Interface to Operating Systems
31