6 trusted computing menu, Kta55/pitx user's guide – Kontron KTA55-pITX User Manual
Page 48
KTD-S0031-E
Page 44
Setup Guide
KTA55/pITX User's Guide
18.5.5.2.1 Enhanced Fan Control Submenu
Feature
Option
Description
Temp 0 Threshold
0°C ...
70°C ... 100°C
Define temperature 0 threshold
PWM 0 Percentage
0% ...
100%
Define PWM 0 percentage
Temp 1 Threshold
0°C ...
60°C ... 100°C
Define temperature 1 threshold
PWM 1 Percentage
0% ...
50% ... 100%
Define PWM 1 percentage
Temp 2 Threshold
0°C ...
50°C ... 100°C
Define temperature 2 threshold
PWM 2 Percentage
0% ...
30% ... 100%
Define PWM 2 percentage
Temp 3 Threshold
0°C ...
40°C ... 100°C
Define temperature 3 threshold
PWM 3 Percentage
0% ... 100%
Define PWM 3 percentage
Temp 4 Threshold
0°C ... 100°C
Define temperature 4 threshold
PWM 4 Percentage
0% ... 100%
Define PWM 4 percentage
Temp 5 Threshold
0°C ... 100°C
Define temperature 5 threshold
PWM 5 Percentage
0% ... 100%
Define PWM 5 percentage
Temp 6 Threshold
0°C ... 100°C
Define temperature 6 threshold
PWM 6 Percentage
0% ... 100%
Define PWM 6 percentage
Temp 7 Threshold
0°C ... 100°C
Define temperature 7 threshold
PWM 7 Percentage
0% ... 100%
Define PWM 7 percentage
Critical Trip Point
0°C ...
85°C ... 100°C
At this point the operating system will shut off the
board
18.6 Trusted Computing Menu
Feature
Option
Description
TPM Support
Disabled
Enabled
Enable or disable TPM support
TPM State
Disabled
Enabled
Set the TPM state
Pending Operation
None
Enable Take Ownership
Disable Take Ownership
TPM Clear
Schedule a TPM operation
Current Status
Information
N / A
Show the current status
TPM Enabled Status
N / A
Show the TPM 'Enabled' status
TPM Active Status
N / A
Show the TPM 'Active' status
TPM Owner Status
N / A