The backlight control signals and supply voltage is available through the connector J1200 (7 pins).

Header

Pin

Signal Name

Function

1

N.C.

Not connected

2

BKLTADJ

Brightness control (0V - +5V)

3

GND

Ground

4

VDD

1)

Backlight voltage

5

VDD

1)

Backlight voltage

6

GND

Ground

1

7

7

BKLTON

Backlight on/off


Note:

1)

To protect the external power lines of peripheral devices make sure that

- the wires have the right diameter to withstand the maximum available current.
- the enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.

6.8

Simultaneous Mode

For simultaneous digital and analog connection from the DVI-I connector a Y-cable is needed. It is impor-
tant that the DDC lines are routed to the DVI monitor otherwise only the analog CRT output is available.

Y-Cable

Note: Without the right DDC connection you have no output on the DVI monitor.