12 digital i/o interface, 1 electrical specifications, 2 connector – Kontron KTA55-pITX User Manual
Page 27: Kta55/pitx user's guide, Digital inputs, Digital outputs
KTD-S0031-E
Page 23
Digital I/O Interface
KTA55/pITX User's Guide
12 Digital I/O Interface
The KTA55/pITX features eight bidirectional I/O lines.
12.1 Electrical Specifications
Digital Inputs
Parameter
Min.
Typ.
Max.
Units
Input LOW voltage
+1.5
V
Input HIGH voltage
+1.5
+3.45
V
Input rate (direct access)
1.6
MHz
Digital Outputs
Parameter
Min.
Typ.
Max.
Units
Output LOW voltage
+0.4
V
Output HIGH voltage
+2.4
+3.3
V
Output LOW/HIGH current
8
mA
Switching rate (direct access)
1.6
MHz
12.2 Connector
The digital I/O interface is available through the connector J1804 (10 pins).
Header
Pin
Signal Name
Function
1
VCC
1)
Power +3.3V
2
GPIO4
Bidirectional I/O 4
3
GPIO0
Bidirectional I/O 0
4
GPIO5
Bidirectional I/O 5
5
GPIO1
Bidirectional I/O 1
6
GPIO6
Bidirectional I/O 6
7
GPIO2
Bidirectional I/O 2
8
GPIO7
Bidirectional I/O 7
9
GPIO3
Bidirectional I/O 3
1
2
9
10
10
GND
Ground
Note:
1)
To protect the external power lines of peripheral devices make sure that
- the wires have the right diameter to withstand the maximum available current.
- the enclosure of the peripheral device fulfills the fire-protecting conditions of IEC/EN 60950.