18 feature connector (feature), Feature connector (feature), Connector definitions – Kontron KTGM45-mITX User Manual
Page 54
KTGM45 Users Guide
KTD-N0793-O
Page 54
3.18
Feature Connector (FEATURE)
Note Pull
U/D
Ioh/
Iol Type
Signal
PIN
Signal Type Ioh/
Iol
Pull
U/D Note
2
2M/
-
I
INTRUDER#
1 2
GND
PWR
-
-
O
S5#
3 4
EXT_SMI#
I
4K7
3
O
PWR_OK
5 6
SB5V
PWR
-
-
-
-
PWR
SB3V3
7 8
EXT_BAT PWR
-
-
-
-
PWR
+5V
9 10
GND
PWR
-
-
1 4K7/ /12mA IOT
GPIO0
11 12
GPIO1
IOT /12mA 4K7/ 1
1 4K7/ /12mA IOT
GPIO2
13 14
GPIO3
IOT /12mA 4K7/ 1
1 4K7/ /12mA IOT
GPIO4
15 16
GPIO5
IOT /12mA 4K7/ 1
1 4K7/ /12mA IOT
GPIO6
17 18
GPIO7
IOT /12mA 4K7/ 1
-
-
PWR
GND
19 20
FAN3OUT O
4K7
3
FAN3IN
21 22
+12V
PWR
-
-
TEMP3IN
23 24
VREF
-
-
PWR
GND
25 26
IRRX
IRTX
27 28
GND
PWR
-
-
1 4K7/
SMBC
29 30
SMBD
4K7/ 1
Notes:
1. Pull-up to +3V3Dual (+3V3 or SB3V3).
2. Pull-up to on-board Battery.
3. Pull-up to +3V3.
Signal
Description
INTRUDER# INTRUDER, may be used to detect if the system case has been opened. This signal’s
status is readable, so it may be used like a GPI when the Intruder switch is not required.
S5#
S5 sleep mode, active low output, optionally used to deactivate external system when in
S5 sleep mode.
EXT_SMI#
External SMI, (active low input) signal can activate SMI interrupt.
PWR_OK
PoWeR OK, signal is high if no power failures are detected. (This is not the same as the
P_OK signal generated by ATX PSU).
SB5V
StandBy +5V supply.
SB3V3
Max. load is 0.75A (1.5A < 1 sec.)
EXT_BAT
(EXTernal BATtery) option for connecting + terminal of an external primary cell battery
(2.5 - 4.0 V) ( – terminal connected to GND etc. pin 10). The external battery is protected
against charging and can be used with or without the on-board battery installed.
+5V
Max. load is 0.75A (1.5A < 1 sec.)
GPIO0..7
General Purpose Inputs / Output. These Signals may be controlled or monitored through
the use of the KT-API-V2 (Application Programming Interface).
FAN3OUT
FAN 3 speed control OUTput. This 3.3V PWM signal can be used as Fan control voltage
(0–3.3V DC in 128 steps) via a Fan Driver Circuit (not included) to program Fan voltage.
For more info, see W83627 datasheet. Default PMW output is 127 (100% = 3.3V).
FAN3IN
FAN3 Input. 0V to +3V3 amplitude Fan 3 tachometer input.
+12V
Max. load is 0.75A (1.5A < 1 sec.)
TEMP3IN
Temperature sensor 3 input. (Recommended: Transistor 2N3904, having emitter
connected to GND (pin 25), collector and basis shorted and connected to pin 23. Further
a resistor 30K/1% shall be connected between pin 23 - 24. (Precision +/- 3ºC).
VREF
Voltage REFerence, reference voltage to be used with TEMP3IN input.
IRRX
IR Receive input (IrDA 1.0, SIR up to 1.152K bps)
IRTX
IR Transmit output (IrDA 1.0, SIR up to 1.152K bps)
SMBC
SMBus Clock signal
SMBD
SMBus Data signal
Connector Definitions