beautypg.com

Functional description cp-rio3-05 – Kontron CP-RIO3-05 User Manual

Page 30

background image

Functional Description

CP-RIO3-05

Page 2 - 8

ID 1044-0711, Rev. 1.0

P R E L I M I N A R Y

Table 2-6: Onboard Serial Port Connector J2 (COM1) Pinout

PIN

SIGNAL

DESCRIPTION

I/O

1

DCD

Data carrier detect

I

2

DSR

Data send request

I

3

RXD

Receive data

I

4

RTS

Request to send

O

5

TXD

Transmit data

O

6

CTS

Clear to send

I

7

DTR

Data terminal ready

O

8

RI

Ring indicator

I

9

GND

Signal ground

--

10

NC

Not connected

--

Table 2-7: Onboard Serial Port Connector J3 (COM2) Pinout

RS-232

PIN

RS-422

I/O

DESCRIPTION

SIGNAL

SIGNAL

DESCRIPTION

I/O

--

Not connected

NC

1

NC

Not connected

--

--

Not connected

NC

2

NC

Not connected

--

I

Receive data

RXD

3

RXD+

Receive data +

I

O

Request to send

RTS

4

TXD+

Transmit data +

O

O

Transmit data

TXD

5

TXD-

Transmit data -

O

I

Clear to send

CTS

6

RXD-

Receive data -

I

--

Not connected

NC

7

NC

Not connected

--

--

Not connected

NC

8

NC

Not connected

--

--

Signal ground

GND

9

GND

Signal ground

--

--

Not connected

NC

10

NC

Not connected

--

Note ...

The RS-232 signals DCD, DTR, DSR, and RI are not supported on the J3
connector.