^TM"
(PA Temperature, GET only)
RSP format: ^TMnnn; where nnn = temperature with range of 0 - 150 degrees C.
^TR"
(TR delayTime for transition from TX->RX, GET/SET)
SET/RSP format: ^TRnn; where nn = the TR delay time with range of 0 - 50 milliseconds .
^VI"
(PA Volts/Current, GET only)
RSP format: ^VIvvv iii; where vvv = the PA voltage with range 00.0 - 99.9 volts, and iii = PA current with
range of 00.0 - 99.9 amps. Note the implied decimal point after the second digit for both values.
^WS"
(Power/SWR, GET only)
RSP format: ^WSppp sss; where ppp = output power in watts and sss = SWR. There is an implied decimal
point after the second s. ppp has a range of 0 - 999 watts, and sss has range of 1.0 - 99.0. sss will return as
000 when not transmitting.
^XI"
(Radio Interface, GET/SET)
SET/RSP format: ^XIno; where n = the transceiver type, and o = a radio-dependent value. The values for
n are:
0
K3 - option byte ignored. Always returns o = 1 in V1.04 and later.
1
BCD - option byte ignored.
2
Analog (Icom voltage levels) - option byte ignored.
3
Elecraft / Kenwood serial I/O. o =1 enables polling of radio for frequency.
4