beautypg.com

Elecraft KPA500 Prog. Reference User Manual

Page 3

background image

^FC"

(Fan Minimum Control, GET/SET)

RSP/SET format: ^FCn; where n = fan minimum speed with range from 0 (off) to 6 (high).

^FL"

(Current Fault, GET/CLEAR)

SET format: ^FLC; clears the current fault.
RSP format: ^FLnn; where nn = current fault identifier. nn = 00 indicates no faults are active.

^NH"

(Enable Inhibit# Input, GET/SET)

SET/RSP format: ^NHn; where n = 1 to enable INHIBIT# input pin, or n = 0 to disable the INHIBIT#
input pin.

^ON "

(Power Status & Off, GET/SET)

SET format: ^ON0; turns the KPA500 off.
RSP format: ^ONn; where n = 1. No response if off.
Note: if a ON; quickly follows a ON0; you _may_ see a ON0; response.
See the ‘P’ command in the BootLoader section for a serial command to turn on the KPA500.

^OS"

(OP/STBY, GET/SET)

SET/RSP format: ^OSn; where n = 0 for Standby, or n = 1 for Operate mode.

^PJ"

(Power Adjustment, GET/SET)

SET/RSP format: ^PJnnn; where nnn = the power adjustment setting wih a range of 80 to 120. The Power
Adjustment value is saved on a per-band basis for the current band. The response indicates the setting for
the current band.

^RVM " (Firmware Release identifier, GET only)

RSP format: ^RVMnn.nn; where nn.nn is the firmware version.

^SN "

(Serial Number, GET only)

RSP format: ^SNnnnnn; where nnnnn - the KPA500 serial number.

^SP"

(Fault Speaker On/Off, GET/SET)

SET/RSP format: ^SPn; where n = 0 for speaker off, or n = 1 for speaker on.

3