Apply Preset Glazing Gaskets to Mullions

A.)

Apply sealant into gasket race a minimum of 2” each direction at each corner.

B.)

Remove glazing gaskets

from the reel and allow to

shrink.

C.)

Cut vertical gaskets D.L.O.
plus 1 ¾”.

D.)

Cut horizontal gaskets
D.L.O. plus ½”.

E.)

Seal all gasket corners: Pull

horizontal gaskets back, seal end,

and compress into the vertical
gasket to insure a snug fit.




F.)

Cut horizontal gaskets at

structural glazed mullions
D.L.O. plus ½”. Cut

vertical spacers to D.L.O.

plus 1 ¼”.







Preset gaskets

Preset gaskets

Note: If the gaskets are difficult to

insert into the gasket race, a
light coat of mineral spirits
can be applied to the gasket

for lubrication.