Series 5900 Silicone Structural Glazed Curtain Wall Installation

Install backer rod foam

at expansion joint.

Closed cell sponge joint plug

Expansion joint

Splice sleeve

½” Between adaptors

Install backer rod foam

at expansion joint.

Splice sleeve

Expansion joint

VIII: Sealant At Splice Joint

Installation of Backer Rods at Structurally Glazed Mullion Splices










Note: At corner mullions, use

more than one backer rod
as required, and miter it to
fit the corner joint.

Reference pages 11 through 13 for mullion splice detail.

Note: Each daylite opening should

be sealed individually with
gaskets and glazing installed,