beautypg.com

Power requirements and installation – Dynojet 224: Pit Eddy Current Brake User Manual

Page 58

background image

Model 224 Pit Eddy Current Brake Installation and User Guide

A P P E N D I X B
Power Requirements and Installation

B-2

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

POWER REQUIREMENTS AND INSTALLATION

The eddy current brake (excluding North America and Japan) requires a dedicated
wall receptacle which must be wired for operation and is included with the brake or
may be shipped in advanced in a separate package.
The eddy current brake requires a dedicated 240VAC single phase power outlet rated
for 30A for proper operation. Failure to follow these instructions could result in
personal injury or damage to the brake.
Connecting the brake to the incorrect
voltage will void the brake warranty. Contact Dynojet with any questions.
The dedicated wall receptacle is a three-pin IEC grounded 30A type and must be
wired in accordance with local building codes and requirements. Installation may
require a licensed electrician to conform to applicable safety standards.

If you are installing your brake in a location other than North America or Japan
and the brake is not equipped with a three pin IEC grounded plug, contact
Dynojet before attempting to connect the brake.

Local and national electrical codes will require that the box containing the receptacle
is grounded.

• This circuit should have a dedicated 30A double pole circuit breaker.
• The brake should be the only device connected to this circuit.