beautypg.com

Dave Smith Instruments TEMPEST User Manual

Page 76

background image

66 System Settings

Dave Smith Instruments

System: MIDI Clock

1 . MIDI: Clock Mode: Off, Master, Slave, Slave Thru—

In Master mode,

Tempest transmits MIDI clock and start, stop, and continue messages.

In Slave mode, Tempest syncs to incoming MIDI clock and responds to start,

stop, and continue messages. When slaved to an external MIDI clock, Tempest’s

Tempo display is preceded by “EXT.” The master BPM (beats per minute) is not

transmitted via MIDI as a numerical value, so Tempest must calculate the BPM

from the incoming clock, and the value displayed by Tempest is subject to round-

ing and the accuracy of the master clock. In other words, Tempest’s displayed

BPM value may be slightly different from the master’s, even though they’re

perfectly synced.

In Slave Thru mode, Tempest syncs to MIDI clock and forwards incoming MMC

and clock messages to the MIDI Out port.

Note:

In Slave and Slave Thru modes, if no MIDI clock is present at the

selected input, Tempest will not play.

When clock mode is set to Off, MIDI clock is neither transmitted nor received.

2 . MIDI: Clock IN Cable: None, MIDI Port, USB—

MIDI Clock data from

another synthesizer or sequencer can be received through either the MIDI Port or

the USB cable. If set to “None” MIDI clock data is ignored.

3 . MIDI: Clock OUT Cable: None, MIDI Port, USB, MIDI•USB—

MIDI

Clock data can be sent out via the MIDI Out port, the USB Port, or both MIDI

and USB. If “None” is selected, MIDI clock out is disabled.

System: MIDI System Exclusive

1 . MIDI: Sysex IN-OUT Cable: None, MIDI Port, USB—

This control allows

you to select either the MIDI port or USB connector for MIDI Sysex data trans-

fers. If “None” is selected, Sysex will be neither transmitted nor received.

Note:

USB Sysex transfers are only supported with Mac OSX and Windows 7.