Page 6
Menu Description
SCREEN
DISPLAY
SET
BST
8.5
SET
+HP
2.0
ALT
2.7
CFG
PT
CAL
48
DESCRIPTION
SETTING BOOST LEVEL
Set this value for the boost you want at your present altitude. The number displayed
will change with altitude and weather if Altitude Compensation is turned on. If
Altitude Compensation is on, then when you set this value, the current ambient
pressure is automatically captured. Ambient pressure is used as the reference point
when adding or subtracting the compensating boost.
SETTING PUSH-TO-PASS
You can set how much extra boost you desire when you press the handlebar button.
ALTITUDE ABOVE SEA LEVEL
This is shown in thousands of feet or thousands of meters. Under normal weather
conditions it will be accurate within about +/-300 feet or +/-100m. Good or
improving weather is associated with high pressure which will make the gauge read
low. Bad or declining weather will make the gauge read high.
CONFIGURATION MODE
In normal mode (showing only the three elements above), a short button press while
ALT is displayed will take you back to the top of the menu (SET HP). Holding the
button for five seconds while the Altitude value is displayed will display CFG and
take you to the configuration menu, described below.
PRESSURE TRANSDUCER CALIBRATION
Calibrate the pressure transducer input to your Boondocker Control Box for proper
fuel regulation, but only if you are not using a separate Boondocker pressure
transducer. Set the Fuel Control Box to show boost by going to the first “STATS”
screen, then adjust this value up or down until control box reads zero boost. See the
calibration procedure above for more details.