Salter Brecknell SBI-505 User Manual
Page 9

7
4 press
press
press
or
[C03 ]
[C03 1]
[C03 5]
Set graduation
option
:1/2/5/10/20/50
Select required graduation
example
:graduation 5:[C03 5]
5 press
press
press
or
/
[C04 ]
[0100.00]
[0100.00]
Max capacity
example
:max weighing 100kg:
[0100.00]
6
press
press
press
press
[C05 ]
[C05 0]
[C05 1]
[CAL 9]
。。。。。。
[0000.00]
Zero calibration
Option
0=no need zero calibration
1=need zero calibration
calibration zero please choose 1 and
ensure scale is empty and “stable”
light is on
Ensure zero calibration, countdown.
Till show[0.00](example for two
decimal point)
。
7 press
press
press
or
press
press
or
press
[C06 ]
[C06 0]
[C06 1]
[SPAN ]
[0100.00]
[0080.00]
[CAL 9]
……
calibration
option:
0=No need calibration
1= need calibration
Load weights on scales
according to max. capacity.
Suggest close to the max
capacity, at least 10% of max.
capacity.
For example: the weights is
80kg