beautypg.com

Salter Brecknell SBI-505 User Manual

Page 9

background image

7

4 press

press

press

or

[C03 ]
[C03 1]
[C03 5]

Set graduation

option

:1/2/5/10/20/50

Select required graduation

example

:graduation 5:[C03 5]

5 press

press

press

or

/

[C04 ]
[0100.00]
[0100.00]

Max capacity

example

:max weighing 100kg:

[0100.00]

6

press

press

press

press

[C05 ]
[C05 0]
[C05 1]
[CAL 9]

。。。。。。

[0000.00]

Zero calibration

Option

0=no need zero calibration

1=need zero calibration

calibration zero please choose 1 and

ensure scale is empty and “stable”

light is on

Ensure zero calibration, countdown.

Till show[0.00](example for two

decimal point)

7 press

press


press

or


press




press

or

press

[C06 ]
[C06 0]

[C06 1]

[SPAN ]
[0100.00]


[0080.00]
[CAL 9]
……

calibration
option:
0=No need calibration
1= need calibration
Load weights on scales
according to max. capacity.
Suggest close to the max
capacity, at least 10% of max.
capacity.

For example: the weights is
80kg

This manual is related to the following products: