beautypg.com

Instruction – Salter Brecknell SBI-505 User Manual

Page 3

background image

1

Instruction

This indicator is designed for basic weighing function.

Main function

Weighing function:
Zero, tare, G.W, N.W, accumulation, printing, animal -weighing.
kg/lb conversion.
Print format: S.N. G.W N.W Tare. Date, Time

Options:
Pinter
RS232/RS485 serial interface or second display

Technical parameter

Accuracy class

6000 e

Resolution

display: 30, 000 ADC: 2,000,000

Zero stability error TK

0

< 0.1μV//K

Span stability error TK

spn

< ± 6 ppm//K

Sensitivity (internal) 0. 3 μV /d

Input voltage

-30~30mV DC

Excitation circuit 5 VDC, 4 wire connection,

Maximum connect 6 load cell of 350Ω

AC power AC100~250V

Operation temperature

- 10 °C ~ + 40 °C

Operation humidity ≤90%RH
Storage temperature

- 40 °C ~ + 70 °C



This manual is related to the following products: