Instruction – Salter Brecknell SBI-505 User Manual
Page 3
![background image](/manuals/634853/3/background.png)
1
Instruction
This indicator is designed for basic weighing function.
Main function
Weighing function:
Zero, tare, G.W, N.W, accumulation, printing, animal -weighing.
kg/lb conversion.
Print format: S.N. G.W N.W Tare. Date, Time
Options:
Pinter
RS232/RS485 serial interface or second display
Technical parameter
Accuracy class
6000 e
Resolution
display: 30, 000 ADC: 2,000,000
Zero stability error TK
0
< 0.1μV//K
Span stability error TK
spn
< ± 6 ppm//K
Sensitivity (internal) 0. 3 μV /d
Input voltage
-30~30mV DC
Excitation circuit 5 VDC, 4 wire connection,
Maximum connect 6 load cell of 350Ω
AC power AC100~250V
Operation temperature
- 10 °C ~ + 40 °C
Operation humidity ≤90%RH
Storage temperature
- 40 °C ~ + 70 °C
This manual is related to the following products: