Salter Brecknell SBI-505 User Manual
Page 18
![background image](/manuals/634853/18/background.png)
16
RS232COM serial interface can receive simple ASCII command.
Command word and role as follows:
Command NAME
Function
T
TARE
Save and clear tare
Z ZERO
Zero
gross
weight
P PRINT
the
weight
R
G.W/N.W
Read gross weight or net weight
C Kg/lb
Kg/lb
conversion
G
G.W
Check gross weight at net weight mode
R command receive data format
Print format
ID.NO. 004
(Serial No.)
Date: XX.XX. XX (yy.mm.dd)
Time: XX.XX.XX (hh.mm.ss)
GROSS 8.88kg (gross weight)
TARE 2.88kg
(tare)
NET 6.00kg
(net weight)
PC or Big display continuous sending format