Salter Brecknell SBI-505 User Manual
Page 17
15
Bits4
unit
:lb=0, kg=1
Bits5 Constant
1
Bits6 Constant
0
State C
Bit2 Bit1 Bit0
unit
0 0 0
Kg
or
lb
0 0 1
g
0 1 0
t
Bit 3
printing=1
Bit 4
Extend
display=1
Bit 5
Constant 1
Bit 6
Constant 0
Computer continuous sending format
,
,
CR LF
S 1 S 2 S 3 Data
S 4
S1:
weight status, ST= standstill, US= not standstill, OL= overload
S2:
weight mode, GS=gross mode, NT=net mode
S3:
weight of positive and negative, “+” or ” –“
S4:
“kg” or “lb”
Data:
weight value, including decimal point
CR:
carriage return
LF:
line feed
Serial interface reception command
: