Salter Brecknell 308BP User Manual
Page 16

xvi
5.2.5 CUSTOM UNIT PROCEDURE (A7)
The custom unit multiplier is the conversion factor that you would multiply grams by in
order to obtain the custom unit of weight. For example, if you wish to display weight in troy
ounces, you would enter in a multiplier value of 0.64301 ( 1 g = 0.64301 ozt). The scale
automatically determines the proper display increment for your custom unit.
1 While in the User Menu, scroll to "A 7", then scroll down once using the MR key to
enter the custom unit multiplier menu.
2. The display will momentarily show "C U" for the custom unit, followed by the current
value for the custom unit multiplier with the decimal point.
3. Use the left or right directional keys (shown in Figure 5-1 above) to move the
decimal point position to the correct position. Pressing the ZERO key or the
SAMPLE key will change the position of the decimal point.
4. After setting the correct decimal point position, press the UNITS key to save it.
5. The display will momentarily show "SET", followed by a value with one flashing digit.
This value will be the current multiplier value with the decimal point position
programmed above.
6. Use the four directional keys (shown in Figure 5-1 above) to adjust the displayed
value to the actual custom unit multiplier value. Increase the flashing digit by
pressing the PRINT key. Decrease the flashing digit by pressing the MR key.
Pressing the ZERO key or the SAMPLE key will change the position of the flashing
digit.
7. After setting the exact value, press the UNITS key to save the custom unit multiplier
value. The display will show "EndCU" momentarily, then revert back up to A7.
5.2.6 EXITING THE USER MENU
1. Exit the User (“A”) menu by first turning the scale OFF, then turning it back ON without
holding down any keys. The display will go through a digit check, then settle into Normal
Operating mode. All front panel keys will now return to their normal mode of operation.
5.2
FACTORY SETUP (“F”) MENU
To enter the “F” menu, power down the scale. Press and hold the PRINT key while powering on the
scale until the scale displays a row of dashes (------) and beeps. Release the PRINT key. Scale now
displays F1. Use the left and right arrow keys to move to another F number. Use the down arrow
key to enter the F number. Use the left and right arrow keys to view and select the choices. Press
SAVE button to accept choice. Use up arrow key to return to F menu.
To exit F menu, go to F24 and press the DOWN arrow key or power off scale. Power on scale to
use for weighing.
Refer to the “F” menu flow diagram and table for more information.