Salter Brecknell 308BP User Manual
Page 13
xiii
CHAPTER 5: SCALE CONFIGURATION
5.1
SCALE CONFIGURATION OVERVIEW
The scale contains two main setup menus: The User (“A”) menu - which configures the serial
communication port and enables some user options - and the Factory Setup (“F”) menu. Both menus
consist of several menu selections, each with its own sub-menu of choices.
5.2
USER (“A”) MENU
5.2.1 ENTERING THE USER MENU
1. Turn OFF the scale.
2. Press and hold the UNITS key while turning the scale back ON.
3. When the scale shows “- - - - - -“, you may release the UNITS key. The scale shows
“A 1”.
5.2.2 NAVIGATING IN THE USER MENU
Use the directional keys shown in Figure 5-1 to move around in the User Menu Chart shown
in Figure 5-2 on the following page.
1. To move to a new “A” heading, use the ZERO (left) or SAMPLE (right) key to move right
or left in the User Menu Chart.
2.
To move to the selection level, press the MR (down) key once. The current saved
selection is shown.
3.
To view the available selections for the current “A” heading, use the ZERO (left) or
SAMPLE (right) key to move through the selection field.
4.
To save a new selection, press the UNITS (Save) key .To exit without saving, press
the PRINT (up) key to return to the current “A” heading.
5.
Repeat Steps 2 through 5 until the User Menu is programmed.
Figure 5-1: User Menu Key Assignments