Self-diagnosis display, Lcd screen – Sony GV-A500 User Manual
Page 40
Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".
![background image](/manuals/629470/40/background.png)
Self-diagnosis display
The VCR has a self-diagnosis display.
This function displa\'s the VCR's condition with
five digits (a combination of a letter and figures)
on the LCD screen, if this occurs, check the
following code chart. The five-digit display
informs you of the VCR's current condition. The
last two digits (indicated by □□) will differ
depending on the state of the VCR.
LCD screen
Self-diagnosis display
•C:Dn:nn
You can service the VCR yourself.
•
Contact your Sony dealer or local
authorized Sony facility.
Five-digit display
Cause and/or corrective actions
C:21:nn
• Moisture condensation has occurred.
Remove the cassette and leave the VCR for at least 1 hour, (p
C:22:DD
• The video heads are dirty.
4 Clean the heads using the Sony V8-25CLH cleaning cassette
supplied), (p. 33)
C:23:nn
• You are using a battery pack that is not an "InfoLITHIUM" ba
pack.
-> Use an "InfoLITHIUM" battery pack. (p. 25)
C:31;Dn
C:32:Dn
• A servicable situation not malfunctioned above has occurred,
•> Remove the cassette and insert it again, then operate the V
7)
Disconnect the power cord of the AC power adaptor or re
the battery pack. After reconnecting the power source, op
the VCR.
E:61;nn
E;62:nn
• A VCR malfunction which you cannot service has occurred
-> Contact your Sony dealer or local authorized Sony servic
and inform them of the five digits, (example: E:61:10)
If you are unable to resolve the problem, contact your Sony dealer or local authorized Sony set
facility.
40