Starting the terminal-emulation software, Figure d-1 – Cisco 3550 User Manual
Page 75
D-3
Catalyst 3550 Multilayer Switch Hardware Installation Guide
OL-6155-01
Appendix D Configuring the Switch with the CLI-Based Setup Program
Accessing the CLI Through the Console Port
Figure D-1
Connecting a Switch Console Port to a PC
Starting the Terminal-Emulation Software
Before you power on the switch, start the terminal emulation session so that you can see the output
display from the power-on self-test (POST).
The terminal-emulation software—frequently a PC application such as Hyperterminal or
ProcommPlus—makes communication between the switch and your PC or terminal possible.
Follow these steps to start a terminal-emulation session:
Step 1
Start the terminal-emulation program if you are using a PC or terminal.
Step 2
Configure the baud rate and character format of the PC or terminal to match these console port default
characteristics:
•
9600 baud
•
8 data bits
•
1 stop bit
•
No parity
•
None (flow control)
1
Catalyst 3550 switch
3
RJ-45-to-DB-9 adapter cable
2
Power cord
100-240V~
5-3A
50/60H
z
DC OUTPUT 1
CONSOLE
101825
1
2