Table 3-1
Common Problems and Solutions
Problem
Solution
System LED is not on, and the
switch does not run POST.
•
Check that the power cable is connected to the switch and to a
known power source.
•
Test the power cable on another switch.
•
Connect a working power cable from another switch.
System LED is amber.
•
An internal fan fault is detected. Either check the switch itself,
or use the show env user EXEC command to check for a failed
fan.
•
The switch might be overheating. Use the show env user EXEC
command to check for an overtemperature condition. If there is
an overtemperature condition:
–
Place the switch in an environment that meets the
environmental requirements given in
–
Make sure that the fan intake and exhaust areas are clear.
•
A fatal POST error is detected. See the
.