AC Test Conditions

Input Pulse Levels ....................................................0V to 3V

Input Rise and Fall Times

................................................. ≤ 5 ns

Input and Output Timing Reference Levels .................... 1.5V

Output Load..................................See

Figure 4

and

Figure 5

Capacitance

(T

A

= 25

°C, f = 1.0 MHz)

Figure 4. AC Output Loading

Figure 5. AC Output Loading for Tristate Specifications

(t

HZ

, t

LZ

, t

WLQZ

, t

WHQZ

, t

GLQX

, t

GHQZ

)

Symbol

Parameter

[2]

Max Units

Conditions

C

IN

Input Capacitance

7

pF

Δ

V = 0 to 3V

C

OUT

Output Capacitance

7

pF

Δ

V = 0 to 3V

577 Ohms

30 pF

789 Ohms

3.0V

INCLUDING

SCOPE AND

OUTPUT

FIXTURE

577 Ohms

5 pF

789 Ohms

3.0V

INCLUDING

SCOPE AND

OUTPUT

FIXTURE

Note

2. These parameters are guaranteed but not tested.