Dell PowerEdge VRTX User Manual
Page 99

Error Code
Message Information
PCI1344
Message
An I/O channel check error was detected.
LCD Message
An I/O channel check error was detected. Power cycle system.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1346
Message
A software error was detected on a component at slot <
number
>.
Action
Reboot the system and update the component drivers.
PCI1348
Message
A PCI parity error was detected on a component at slot <
number
>.
LCD Message
PCI parity error on slot <
number
>. Re-seat PCI card.
Details
System performance may be degraded, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1350
Message
A PCI system error was detected on a component at slot <
number
>.
LCD Message
PCI parity error on slot <
number
>. Re-seat PCI card.
Details
System performance may be degraded, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1354
Message
A bus correctable error was detected on a component at slot
<
number
>.
Details
System performance may be degraded.
Action
Cycle input power, update component drivers, remove and reinstall
the device at the next scheduled service time.
PCI1356
Message
A bus uncorrectable error was detected on a component at slot
<
number
>.
Details
System performance may be degraded, or system may fail to operate.
Action
Cycle input power, update component drivers, if device is removable,
reinstall the device.
PCI1358
Message
A fatal error was detected on a component at slot <
number
>.
LCD Message
Fatal error on slot <
number
>. Re-seat PCI card.
Details
System performance may be degraded, or system may fail to operate.
99