Error Code
Message Information
Action
Check the system operating environment and review event log for fan
failures.
TMP0115
Message
The <
name
> temperature is greater than the upper critical threshold.
LCD Message
The <
name
> temperature is outside of range. Check Fans
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
Check the system operating environment and review event log for fan
failures.
TMP0116
Message
The <
name
> temperature is outside of range.
LCD Message
The <
name
> temperature is outside of range. Check Fans
Action
Check the system operating environment and review event log for fan
failures.
TMP0118
Message
The system inlet temperature is less than the lower warning
threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0119
Message
The system inlet temperature is less than the lower critical threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too cool.
Action
Check the system operating environment.
TMP0120
Message
The system inlet temperature is greater than the upper warning
threshold.
LCD Message
System inlet temperature is outside of range.
Details
Ambient air temperature is too warm or one or more fans may have
failed.
Action
Check the system operating environment and review event log for fan
failures.
TMP0121
Message
The system inlet temperature is greater than the upper critical
threshold.