CPU0701

Message

CPU <

number

> protocol error detected.

LCD Message

CPU <

number

> protocol error detected. Power cycle system.

Details

System event log and operating system logs may indicate that the
exception is external to the processor.

Action

1. Check system and operating system logs for exceptions. If no

exceptions are found, continue.

2. Turn system off and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn system on.
5. If the issue persists, see

Getting Help

.

CPU0702

Message

CPU bus parity error detected.

LCD Message

CPU bus parity error detected. Power cycle system.

Details

System event log and operating system logs may indicate that the
exception is external to the processor.

Action

1. Check system and operating system logs for exceptions. If no

exceptions are found, continue.

2. Turn system off and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn system on.
5. If the issue persists, see

Getting Help

.

CPU0703

Message

CPU bus initialization error detected.

LCD Message

CPU bus initialization error detected. Power cycle system.

Details

System event log and operating system logs may indicate that the
exception is external to the processor.

Action

1. Check system and operating system logs for exceptions. If no

exceptions are found, continue.

2. Turn system off and remove input power for one minute.
3. Ensure the processor is seated correctly.
4. Reapply input power and turn system on.
5. If the issue persists, see

Getting Help

.