Dell PowerEdge VRTX User Manual
Page 136

Error Code
Message Information
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
VLT0228
Message
The memory module <
name
> voltage is outside of range.
LCD Message
Memory module <
number
> <
name
> voltage is outside of range.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-configure the system to minimum configuration, inspect and
reinstall system cables.
VLT0230
Message
The PCIe mezzanine card <
number
> <
name
> voltage is less than the
lower warning threshold.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
2. Re-seat the PCIe mezzanine card.
3. If the issue persists, see
VLT0231
Message
The PCIe mezzanine card <
number
> <
name
> voltage is less than the
lower critical threshold.
Details
System hardware detected an over voltage or under voltage
condition.
If multiple voltage exceptions occur consecutively the system may
power down in fail-safe mode.
Action
1. Review system logs for power supply exceptions.
136