Error Code
Message Information
PSU0004
Message
The power input for power supply <
number
> is outside of the
allowable range.
LCD Message
Power input for PSU <
number
> is outside of range. Check PSU
cables.
Details
The operating requirements for the power supply may be found in this
manual or on the power supply itself.
Action
Verify the input source is attached to the power supply. Verify the
input power is within the operating requirements for the power
supply.
PSU0005
Message
The power input for power supply <
number
> is outside of the
allowable range, but it is attached to the system.
Details
The operating requirements for the power supply may be found in this
manual or on the power supply itself.
Action
Verify the input power is within the operating requirements for the
power supply.
PSU0006
Message
Power supply <
number
> type mismatch.
LCD Message
Power supply <
number
> is incorrectly configured. Check PSU.
Details
Power supplies should be of the same input type and power rating.
Action
Install matched power supplies and review proper configuration in
this manual.
PSU0007
Message
Power supply <
number
> is operating at 110 volts, and could cause a
circuit breaker fault.
Details
A power supply that is designed to operate at 220V, but is connected
to a 110V power source requires additional current for operation. The
additional current may trip circuit-breakers or cause other electrical
issues with the input source.
Action
Check input power source and cabling. Use recommended input
power. Review this Manual. If the issue persists, see
.
PSU0008
Message
Power supply <
number
> voltage rating does not match the system's
requirements.
Details
The system does not support mixed voltage power supplies.
Action
Install a power supply with the correct voltage rating.
PSU0016
Message
Power supply <
number
> is absent.