Dell PowerVault LTO3-060 User Manual
Page 52
17
Activate Error
18
Threshold Error
19
Suspend Lifted
1A
Block Pool Error
1B
Queue Function Failed
1C
Semaphore Function Failed
1D
Timer Function Failed
1F
Thread Function Failed
20
Command Started
21
System Failure
22
System Busy
23
System Timeout
24
Software Error
25
Hardware Error
Message Error Types
26
Message Sender (Task ) ID
Error
l
.
l
Check host adapter and SAS cables.
l
Power cycle the autoloader and retry the operation.
l
If all previous steps fail, see
Contacting Dell
.
27
Message Type Bad
28
Message Parameter Bad
Stack/Global Data Corruption Error Types
29
Invalid Element
l
.
l
Power cycle the autoloader.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
l
If all previous steps fail, see
Contacting Dell
.
2A
Invalid Element Status
2B
Element Table Bad
2C
Global Data Bad
2D
Stack Data Bad
2E
Task Stack Low
2F
Task Stack Overflow
System Shutdown/Disruption Error Types
30
POST Failure
l
Verify that the magazines/magazine blank are fully seated.
l
Power cycle the autoloader.
l
If all previous steps fail, see
Contacting Dell
.
31
Watchdog Timer
l
Power cycle the autoloader.
l
Run the Random Moves test from either the Remote Management Unit (RMU) or the Operator Control
Panel (OCP).
Note: The Random Moves test requires a minimum of two cartridges present within the autoloader.
l
Check
for PowerVault 124T firmware updates.
l
see
Contacting Dell
.
32
Power Event
33
Power Down Failure
34
System Overload
35
System Performance
36
Asynchronous Stop
System Miscellaneous Error Types
37
System Cleaning Error
Cleaning slot in use.
l
Verify that a valid cleaning cartridge is located in the dedicated cleaning slot indicated within the
Remote Management Unit Configuration page settings.
l
Check
for PowerVault 124T firmware updates.
l
If all previous steps fail, see
Contacting Dell
.
38
System Internal I2C HW Error
See
Contacting Dell
.
39
ALD (Autoloader Diagnostic)
Limits Error
This error may occur as a result of a failed diagnostic test.
l
If the Magazine Test or Inventory Test failed, remove and inspect the magazines
one at a time. Turn the white thumbwheels on each magazine and insure that the carriers move
freely at
least one full rotation in each direction. Re-insert each magazine after inspection.
l
If the Picker Test failed, verify there is no obstruction within the picker assembly and repeat the test.