Attributes, Schema extensions – Dell KVM 2321DS User Manual
Page 157
LDAP Feature for the Remote Console Switch
141
Attributes
There is one more hierarchy used in AD. Associated with each object class is a
set of “attributes” used to store specific information about the entity that is
being represented. For example, associated with the User object class is an
attribute type named SAM ACCOUNT NAME and others such as FIRST
NAME, SURNAME, PASSWORD, etc. The suite of Dell Remote Console
Switches uses the SAM ACCOUNT NAME and PASSWORD attributes to
authenticate a user (the formal AD names for these two attributes are
sAMAccountName and unicodePWD, respectively).
Schema Extensions
AD is packaged with many object classes, including default containers for
Computer and User objects as well as classes for OU containers and classes to
represent computer and user entities. AD can be extended to include new
object classes such as those provided by Dell to simplify the administration of
access controls; such extensions are usually referred to as “schema extensions”
and are at the heart of the Dell Extended Schema feature described in this
document. These schema extensions provide customized object classes to
represent Dell Remote Console Switches, access control information, and a
type of container used to associate specific access control information with
specific instances of Dell Remote Console Switches and Users. It is important
to note that each attribute type and object class used in AD must have a
globally unique identifier, known as an Object Identifier (OID). These
unique identifiers are ultimately managed by internationally recognized
authorities. For AD, the OID space is managed secondarily by Microsoft. Dell
has obtained OIDs for the custom object classes and attribute types used in
the Dell Extended Schema feature. The following is a summary of the OIDs
Dell obtained:
Dell extension is: dell
Dell base OID is: 1.2.840.113556.1.8000.1280
RCS LinkID range is: 12070 to 12079
The suite of Dell Remote Console Switches is also designed to function using
only object classes present in the AD packaged classes; this option is known as
the Standard Schema. Under this option, the Computer object class is used
to represent Dell Remote Console Switches and standard Group objects are