Dell PowerEdge 650 User Manual
Page 24
Invalid memory
configuration
detected. Potential
corruption exists!
Keyboard controller
failure
Faulty keyboard controller (faulty
system board).
See "
Getting Help
."
Keyboard data line
failure
Keyboard failure
Keyboard stuck key
failure
Loose or improperly connected
keyboard cable; faulty keyboard;
faulty keyboard controller.
Ensure that the keyboard is properly connected. If the problem persists, replace the
keyboard. If the problem persists, see "
Getting Help
."
Memory address line
failure at address,
read value expecting
value
Memory double word
logic failure at
address, read value
expecting value
Memory odd/even logic
failure at start
address to end address
Memory write/read
failure at address,
read value expecting
value
Faulty or improperly installed memory
modules, or faulty system board.
Ensure that all memory modules are properly installed. If the problem persists, replace
the memory module(s). See "
Removing Memory Modules
" and "
Installing Memory Modules
"
in "Installing System Components." If the problem persists, see "
Getting Help
."
Memory allocation
error
Faulty application program.
Restart the application program.
Memory bank population
error!
Memory modules are not installed in
decreasing size with the largest size
of memory modules in bank 1; faulty
memory module(s); memory modules
are not installed sequentially.
Ensure that the memory modules are properly installed. Ensure that the memory modules
are populated sequentially. See "
Memory Module Installation Guidelines
" in "Installing
System Components." If the problem persists, replace the specified memory modules. See
"
System Memory
" in "Installing System Components."
Memory parity
interrupt at address
Faulty or improperly installed memory
modules.
Ensure that all memory modules are properly installed. If the problem persists, replace
the memory module(s). See "
Removing Memory Modules
" and "
Installing Memory Modules
"
in "Installing System Components."
Memory tests
terminated by
keystroke
The spacebar was pressed during
POST to terminate the memory test.
Information only.
No boot device
available
Faulty or missing diskette/CD-drive
subsystem, hard drive, or hard-drive
subsystem.
Check the Integrated Devices configuration settings in the System Setup program. See
"Using the System Setup Program" in your User's Guide. Ensure that either SCSI
Controller, Diskette Controller, or IDE CD-ROM Controller is enabled. If booting from a
SCSI controller, ensure that the controller is properly connected. If the problem persists,
replace the diskette/CD drive subsystem. See "
Removing the CD and Diskette Drives
" in
"Installing Drives." If the problem persists, replace the faulty hard drive. See "
Hard Drives
"
in "Installing Drives."
No boot sector on
hard-disk drive
No operating system on hard drive.
Check the hard-drive configuration settings in the System Setup program. See "Using the
System Setup Program" in your User's Guide.
No timer tick
interrupt
Faulty system board.
See "
Getting Help
."
Faulty diskette, diskette/CD-drive
assembly, hard drive, or hard-drive
Use a bootable diskette. If the problem persists, replace the diskette/CD-drive
subsystem. See "
Removing the CD and Diskette Drives
" in "Installing Drives." If the