beautypg.com

Switching waveforms – Cypress CY62138EV30 User Manual

Page 6

background image

CY62138EV30

MoBL

®

Document #: 38-05577 Rev. *A

Page 6 of 9

Read Cycle No. 2 (OE Controlled)

[14, 15]

Write Cycle No. 1 (WE Controlled)

[16, 18]

Notes:

15. Address valid prior to or coincident with CE transition LOW.
16. Data I/O is high impedance if OE = V

IH

.

17. During this period, the I/Os are in output state and input signals should not be applied.
18. If CE goes HIGH simultaneously with WE HIGH, the output remains in high-impedance state.

Switching Waveforms

(continued)

50%

50%

DATA VALID

t

RC

t

ACE

t

DOE

t

LZOE

t

LZCE

t

PU

DATA OUT

HIGH IMPEDANCE

IMPEDANCE

I

CC

I

SB

t

HZOE

t

HZCE

t

PD

OE

CE

HIGH

V

CC

SUPPLY

CURRENT

ADDRESS

t

HD

t

SD

t

PWE

t

SA

t

HA

t

AW

t

WC

DATA I/O

ADDRESS

CE

WE

OE

t

HZOE

DATA

IN

VALID

NOTE

17

t

SCE

[+] Feedback