Ring and call waiting tone spec – Cisco Linksys SPA9000 User Manual
Page 175

6-27
Linksys SPA9000 Administrator Guide
Document Version 3.01
Chapter 6 SPA9000 Field Reference
Regional Tab
Ring and Call Waiting Tone Spec
Ring5 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 5 for the inbound
call.
The default is Bellcore-r5.
Ring6 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 6 for the inbound
call.
The default is Bellcore-r6.
Ring7 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 7 for the inbound
call.
The default is Bellcore-r7.
Ring8 Name
Name in an INVITE’s Alert-Info Header to pick distinctive ring/CWT 8 for the inbound
call.
The default is Bellcore-r8.
Field
Description
Ring Waveform
Waveform for the ringing signal.
The default is Sinusoid.
Ring Frequency
Frequency of the ringing signal. Valid values are 10–100 (Hz).
The default is 25.
Ring Voltage
Ringing voltage. 60–90 (V).
The default is 70.
CWT Frequency
Frequency script of the call waiting tone. All distinctive CWTs are based on this tone.
The default is 440@-10.