beautypg.com

Thermal impedances, Solder reflow peak temperature – Cypress CapSense CY8C20396 User Manual

Page 28

background image

CY8C20x36/46/66, CY8C20396

Document Number: 001-12696 Rev. *D

Page 28 of 34

Figure 18. 48-Pin (7x7 mm) QFN

Important Notes

For information on the preferred dimensions for mounting QFN packages, see the following Application Note at

http://www.amkor.com/products/notes_papers/MLFAppNote.pdf

.

Pinned vias for thermal conduction are not required for the low power PSoC device.

Thermal Impedances

Solder Reflow Peak Temperature

This table lists the minimum solder reflow peak temperature to achieve good solderability.

001-13191 *C

Table 33. Thermal Impedances per Package

Package

Typical

θ

JA

[11]

16 QFN

32.69

o

C/W

24 QFN

[12]

20.90

o

C/W

32 QFN

[12]

19.51

o

C/W

48 SSOP

69

o

C/W

48 QFN

[12]

17.68

o

C/W

Table 34. Solder Reflow Peak Temperature

Package

Minimum Peak Temperature

[13]

Maximum Peak Temperature

16 QFN

240

o

C

260

o

C

24 QFN

240

o

C

260

o

C

32 QFN

240

o

C

260

o

C

48 SSOP

220

o

C

260

o

C

48 QFN

240

o

C

260

o

C

Notes

11. T

J

= T

A

+ Power x

θ

JA

.

12. To achieve the thermal impedance specified for the QFN package, the center thermal pad must be soldered to the PCB ground plane.
13. Higher temperatures may be required based on the solder melting point. Typical temperatures for solder are 220 ± 5

o

C with Sn-Pb or 245 ± 5

o

C with Sn-Ag-Cu paste.

Refer to the solder manufacturer specifications.

[+] Feedback