beautypg.com

Technical data – Baumer N 140 User Manual

Page 18

background image

N 140

www.baumer.com

18

7. Technical data

Technical data – electrical ratings
Supply voltage

24 VDC ±10 %

Current consumption

≤30 mA

Display

LCD, 7-segment display, 2-lines, backlit

Measuring principle

Absolute multiturn sensing

Measuring range

-999,99...+9999,99 mm

-99.999...+999.999

inch

Steps per turn

2304

Number of turns

4096 / 12 bit

Spindle pitch

≤23 mm

Interface

RS485 (ASCII-protocol)

Data memory

Parameter buffer: EEPROM

Current value buffer: >10 years by

integrated 3 V lithium battery

Programmable parameters

Display position horizontal/vertical

Measuring unit mm/inch

Counting

direction

Spindle

pitch

Spindle

tolerances

Positioning

direction

Direction

arrows

Tolerance

window

Round

up/down

Standard DIN EN 61010-1

Protection II

Overvoltage category II

Pollution degree 2

Emitted interference

DIN EN 61000-6-3

Interference immunity

DIN EN 61000-6-2

Approvals

UL/cUL



Technical data – mechanical design
Hollow shaft

ø20 mm, ø25 mm

Operating speed

≤600 rpm (short-term)

Protection DIN EN 60529

IP 65 (housing), IP 40 (connector)

Operating temperature

-10...+50 °C

Storage temperature

-20...+70 °C

Relative humidity

80 % not condensing

Torque support

Torque pin provided at housing

E-connection

- Cable output (30 cm) with male and mating connector M16, 5-pins

Housing type

Surface-mount with hollow shaft

Dimensions W x H x L

56 x 100 x 62.5 mm

Mounting

Surface-mount with hollow shaft

Weight approx.

200 g

Material

Polycarbonate black, UL 94V-0