Error warnings, Overview on commands, Crc error – Baumer N 140 User Manual
Page 17: Format error
N 140
www.baumer.com
17
5. Error warnings
5.1. CRC error
Upon recognizing a CRC error in a transmitted command the SPA will respond as follows:
SOH
Adr
Error
EOT
CRC
Response
01h
20h
65h
04h
46h Error = „e“ (65h) = CRC error
5.2. Format error
Upon recognizing a format error (incorrect length of protocol or void command (Cmd) in a transmitted command
the SPA will respond as follows:
SOH
Adr
Error
EOT
CRC
Response
01h
20h
66h
04h
40h Error = „f“ (66h) = Format error
6. Overview on commands
The following chart shows in alphabetical order all available commands (Cmd) as well as options regarding read
and write (parameterization).
Command
code
Data amount
in bytes
read
write
Broad-
cast
Save in
EEPROM
Significance
a (61h)
5
X
X
-
X
Read / write general parameters
b (62h)
8
X
X
-
X
Parameter: tolerance compensation, window
c (63h)
8
X
X
-
X
Parameter: scaling factor spindle pitch
i (69h)
1
X
X
X
X
Parameter: mm / inch
t (74h)
6
-
X
-
-
Transmit tool number
u (75h)
6
-
X
-
-
Transmit optional number sequence
x (78h)
5
X
X
-
X
Read / write specific parameters
A (41h)
2
X
X
X
X
Assign or show device identifier
C (43h)
3 / 11
X
-
-
-
Check if actual value = target
K (4Bh)
-
-
X
X
X
Specific command: Profile reset (delete)
Q (51h)
1
-
X
X
X
Specific command: N 140 reset
R (52h)
6
X
-
-
-
Read current value
S (53h)
8
X
X
-
X
Read/write target value
U (55h)
6
X
X
-
-
Offset
V (56h)
2
X
X
X
X
Read / write profile number
X (58h)
2 / 4 / 8
X
-
-
-
Specific command: read device data
Z (5Ah)
6
X
X
X
X
Set preset