Specific commands, Spa profile reset, command „k“ (4bh) – Baumer N 140 User Manual
Page 15

N 140
www.baumer.com
15
4.5. Specific commands
Command
code
Data amount
in bytes
read
write
Broad-
cast
Save in
EEPROM
Significance
K (4Bh)
-
-
X
X
X
Specific command: Profile reset (delete)
Q (51h)
1
-
X
X
X
Specific command: N 140 reset
X (58h)
2 / 4 / 8
X
-
-
-
Specific command: Read device data
4.5.1. SPA profile reset, command „K“ (4Bh)
This command is clearing all previously programmed profiles.
Example 1: Profile reset of a specific N 140
SOH
Adr
Cmd
Data
EOT
CRC
Transmisison
01h
20h
4Bh
7Fh
04h
C6h
SOH
Adr
Data
EOT
CRC
Response
01h
20h
6Fh
04h
52h N 140 replies by standard response ‚o’ (6Fh) = OK
Example 2: General profile reset at all N 140 by broadcast command (identifier = 99)
SOH
Adr
Cmd
Data
EOT
CRC
Transmission
01h
83h
4Bh
7Fh
04h
DBh
Response
Not confirmed
Important: After profile reset all profile data are set to auf FFFFFFhex , the current profile number to FFhex.
The display now shows 6 dashes instead of the target.
4.5.2. N 140 restore default, command „Q“ (51h)
This command restores default either of individual or collective parameters.
Data = q (71h) = Restore default
Data = r (72h) = Controller reset
Data = t (74h) = Device identifier = 0.
Data = x (78h) = Multiturn counter is set to 4096 corresponding to 0.
Data = ∆ (7Fh) = All above functions except „r“ (72h) are enabled.
Parameter function „r“ is only enabled individually.
Note: No profile reset. Profile reset by command „R“.
Example 1: Restore default of specific N 140
SOH
Adr
Cmd
Data
EOT
CRC
Transmisison
01h
20h
51h
7Fh
04h
AEh
SOH
Adr
Data
EOT
CRC
Response
01h
20h
6Fh
04h
52h N 140 replies by standard response ‚o’ (6Fh) = OK
Example 2: Restore default at all N 140 by broadcast command (identifier=99)
SOH
Adr
Cmd
Data
EOT
CRC
Transmision
01h
83h
51h
7Fh
04h
B3
Response
Not confirmed