6. Error
messages
Error messages are visualized by a flashing upper display, alternating between error code and the presently ac-
tive value (normally the target).
MAX limit of the SPA hurt by manual positioning operation.
Troubleshooting: Get SPA back to permitted positioning range.
MIN limit of the SPA hurt by manual positioning operation.
Troubleshooting: Get SPA back to permitted positioning range.
SPA does not attain the target window.
Troubleshooting: Extend tolerance window. Switch to crawling speed at an earlier point.
The target transmitted is outside the MAX limit.
Note: Consider loop operations.
Troubleshooting: Transmit new permissible position value.
The target transmitted is outside the MIN limit.
Note: Consider loop operations.
Troublehsooting: Transmit new permissible position value.