Direct positioning „sd, N 143 – Baumer N 143 User Manual
Page 12
N 143
12 www.baumer.com
Direct positioning „SD“
This command is utilized for direct positioning operations. Only the current value without profile number will be
transmitted to the SPA.. Instead of transmitting the profile number, command “S” is followed by sub-command
“D” (dimension). Motor start requires the additional enable signal in command “D” .
Example: Set position value for direct positioning (without profile number):
SOH Adr Cmd Sub
Position value = 278,25
EOT CRC
Transmission
01h 20h 53h 44h 30h 32h 37h 38h 32h 35h
04h 6Bh
SOH Adr Cmd Sub
Position value = 278,25
EOT CRC
Response
01h 20h 53h 44h 30h 32h 37h 38h 32h 35h
04h
6Bh
Note: The position value will not be saved in the non-volatile memory. Consequently it is not retained after
power off but the previously active profile will be restored.
Target transmission with simultaneous motor enable signal
Some applications require automated self-positioning of a specific shaft when being provided with the new tar-
get without prior transmission of the enable signal in command „D“. The following commands serve this inten-
tion:
SPF transmits the profile value to the SPA. Motor start enabled for automated positioning
SDF transmits the position value to the SPA. Motor start enabled for automated positioning
Attaching the sub-command „F“ to the respective basic command will enable the addressed SPA. Groups re-
main unaffected, since only specific individual positioning operations are required. The operator must see that
any collisions are avoided.
Example: Set a specific target using command „SPF“ (profile no. = 17; target = -12.50)
SOH Adr Cmd Sub1 Sub2 Profile=17
target = -12,50
EOT CRC
Transmission
01h 20h 53h 50h 46h 31h
37h 2Dh 30h
31h
32h
35h
30h
04h A0h
SOH Adr Cmd Sub1 Sub2 Profile=17
target = -12,50
EOT CRC
Response
01h 20h 53h 50h 46h 31h
37h 2Dh 30h
31h
32h
35h
30h
04h A0h