Command overview, Crc error, Format error – Baumer N 143 User Manual
Page 27
N 143
www.baumer.com
27
4.6. CRC error
Upon identification of a CRC error in a command transmitted, the positioning display will reply by the following
response:
SOH Adr Error EOT CRC
Response
01h 20h 65h 04h 46h Error = „e“ (65h) = CRC error
4.7. Format error
Upon identification of a format error in a command transmitted (incorrect length of protocol or unvalid command
(Cmd), the positioning display will reply by the following response:
SOH Adr Error EOT CRC
Response
01h 20h 66h 04h 40h Error = „f“ (66h) = Format error
5. Command
overview
In the following table is a list of all available commands (Cmd) in alphabetical order, along with the correspond-
ing read and write access.
Command
code
Data length
in bytes
read
write
Broad-
cast
Saved in
EEPROM
Functionality
a (61h)
5
X
X
-
X
Read/write general parameters
b (62h)
8
X
X
-
X
Parameters: Backlash, tolerance window
c (63h)
8
X
X
-
X
Parameter: Pitch scaling
g (67h)
12
X
X
-
X
Parameter: MIN and MAX limits
h (68h)
12
X
X
-
X
Parameter: Motor speed switching points
i (69h)
1
X
X
X
X
Parameter: mm / inch
k (6Bh)
9
X
X
-
X
Parameter: Motor system times
m (6Dh)
5
X
X
-
X
Read/write general parameters
t (74h)
6
-
X
-
-
Transmit tool number
u (75h)
6
-
X
-
-
Transmit available number sequence
x (78h)
5
X
X
-
X
Read/write specific parameters
A (41h)
2
X
X
X
X
Allocate or indicate device address
B (42h)
2
-
-
-
-
SPA response in addressing mode
C (43h)
3 / 11
X
-
-
-
Verify if current value = target
D (44h)
1
X
X
X
-
Motor start signal
F (46h)
4
X
-
-
-
Read out device status and device error
K (4Bh)
-
-
X
X
X
Specific command: Clear (delete) profile
Q (51h)
1
-
X
X
X
Specific command: N 143 reset
R (52h)
6
X
-
-
-
Read current value
S (53h)
8
X
X
-
X
Read/write target value
U (55h)
6
X
X
-
-
Offset
V (56h)
2
X
X
X
X
Read/write profile number
X (58h)
2 / 4 / 8
X
-
-
-
Specific command: Read device data
Z (5Ah)
6
X
X
X
X
Set preset